{"id":133009,"date":"2024-01-01T04:55:38","date_gmt":"2024-01-01T12:55:38","guid":{"rendered":"https:\/\/www.stevenrhine.com\/?p=133009"},"modified":"2024-01-01T06:41:57","modified_gmt":"2024-01-01T14:41:57","slug":"mettler-toledo-bc60-bca-222-60u-pitney-bowes-jp85-scale-teardown","status":"publish","type":"post","link":"https:\/\/www.stevenrhine.com\/?p=133009","title":{"rendered":"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown"},"content":{"rendered":"<p>Mettler Toledo BC60 BC6L BCA-222-60U (Pitney Bowes JP85) Scale Teardown<\/p>\n<p>While browsing through eBay, I stumbled upon a valuable addition for the shop\u2014a Pitney Bowes JP85, which is Just a rebranded <a href=\"https:\/\/www.mt.com\/ca\/en\/home\/products\/Transport_and_Logistics_Solutions\/postal_scales_transp_log\/BC-Scale.html\">Mettler Toledo BC60<\/a> Series BC6L scale. Despite having with a plastic platter, I discovered that the stainless platter from my existing <a href=\"https:\/\/www.stevenrhine.com\/?p=64762\">Mettler Toledo PS60<\/a> fit seamlessly. Every component underwent a thorough check, and I&#8217;m pleased to report that everything is in perfect working order. I also Snagged a Second Display for it The prospect of having two displays is a welcomed bonus many time i have placed something on the scale went to the PC and forgot the weight LOL.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-133012\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-1024x576.jpg\" alt=\"\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-2048x1152.jpg 2048w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><br \/>\nLets Take it Appart!<\/p>\n<p>Mettler Toledo BC60 BC6L BCA-222-60U (Pitney Bowes JP85) Scale Display Removed..<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Display-Removed-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-133015\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Display-Removed-1024x576.jpg\" alt=\"Mettler Toledo BC60 BC6L BCA-222-60U (Pitney Bowes JP85) Scale Display Removed\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Display-Removed-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Display-Removed-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Display-Removed-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Display-Removed-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Display-Removed-2048x1152.jpg 2048w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><br \/>\nMianboard Cover Removed.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Cover-Removed-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-133016\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Cover-Removed-1024x576.jpg\" alt=\"Mettler Toledo BC60 BC6L BCA-222-60U (Pitney Bowes JP85) Scale Main Board Cover Removed.\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Cover-Removed-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Cover-Removed-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Cover-Removed-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Cover-Removed-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Cover-Removed-2048x1152.jpg 2048w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><br \/>\nBack Of Mettler Toledo BC60 BC6L BCA-222-60U Main Board. Remove 2 Screws.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Back-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-133017\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Back-1024x576.jpg\" alt=\"Mettler Toledo BC60 BC6L BCA-222-60U (Pitney Bowes JP85) Scale Main Board Back\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Back-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Back-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Back-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Back-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Back-2048x1152.jpg 2048w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><br \/>\nAfter Disconnecting the Load Cell The Main Board is Free..<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Removed-Close-Up-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-133020\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Removed-Close-Up-1024x576.jpg\" alt=\"\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Removed-Close-Up-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Removed-Close-Up-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Removed-Close-Up-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Removed-Close-Up-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-Removed-Close-Up-2048x1152.jpg 2048w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><br \/>\nThis Scale Packs a <a href=\"https:\/\/www.nxp.com\/docs\/en\/data-sheet\/LPC1769_68_67_66_65_64_63.pdf\">NXP LPC1768FBD100<\/a> Conveniently Mettler Toledo Labled the JTAG in nice large Letters, Sadly None of My Xeltek Programmers Support this for In-circuit Programming so I WIll have to Use alternate Method Such as J-link to make a firmware backup.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-LPC1768FBD100-MCU-JTAG-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-133022\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-LPC1768FBD100-MCU-JTAG-1024x576.jpg\" alt=\"\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-LPC1768FBD100-MCU-JTAG-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-LPC1768FBD100-MCU-JTAG-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-LPC1768FBD100-MCU-JTAG-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-LPC1768FBD100-MCU-JTAG-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-Main-Board-LPC1768FBD100-MCU-JTAG-2048x1152.jpg 2048w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><br \/>\nFrom the foot Print by the JTAG Letters it looks like a Standard Cortex Debug Connector layout (10-pins, 0.05&#8243;) just missing the connector (For Now) Connector is a <a href=\"https:\/\/www.samtec.com\/products\/ftsh-105-01-l-dv-k\">FTSH-105-01-L-DV-K<\/a><br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/concortex10pindesc.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-133024\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/concortex10pindesc.png\" alt=\"\" width=\"299\" height=\"165\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/concortex10pindesc.png 330w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/concortex10pindesc-300x165.png 300w\" sizes=\"auto, (max-width: 299px) 100vw, 299px\" \/><\/a><br \/>\nUpdate I decided to read the <a href=\"https:\/\/www.mt.com\/us\/en\/home\/library\/operating-instructions\/industrial-scales\/GSP_BC_Scale_SM\/_jcr_content\/mainpar\/download\/file\/file.res\/30126862_R02_BC_Scale_SM_EN.pdf\">BC Scale Service Manual<\/a>, Page 105 Section 5.2 Update Scale Software 5.2.1 Update By USB.<\/p>\n<p>To get to the firmware you can hold the left arrow key while plugging it in and release the screen will be blinking and will show as a drive on your computer with a firmware.bin file inn the directory, Just copy this file you have backed up your firmware. I am on Software Number: 30233384 Version: 1.00.015\u00a0 (<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Pitney-Bowes-JP85-Scale-1.00.015-30233384-Firmware.zip\">My Backup<\/a>).<\/p>\n<p>I&#8217;ve identified a Winbond 25X40CL EEPROM on the board U17. I plan to read this to potentially uncover valuable information such as the Scale Model Number, Serial Number, and Calibration Data. Considering the likelihood that this EEPROM stores indispensable data, losing it due to an EPROM failure or corruption would be a significant setback, possibly requiring the purchase of an entire board from Mettler Toledo, the costs of which are uncertain. In the service manual trouble shooting there is a lot of eprom errors and eprom is broken. I am Eager to safeguard this information, I&#8217;m set on backing it up and delving into a deeper understanding of my scale. Stay tuned for updates on this intriguing exploration!<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Pitney-Bowes-JP85-Mettler-Toledo-BC-60-Scale-Eprom-Is-Broken.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-133029\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Pitney-Bowes-JP85-Mettler-Toledo-BC-60-Scale-Eprom-Is-Broken.jpg\" alt=\"\" width=\"498\" height=\"365\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Pitney-Bowes-JP85-Mettler-Toledo-BC-60-Scale-Eprom-Is-Broken.jpg 605w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Pitney-Bowes-JP85-Mettler-Toledo-BC-60-Scale-Eprom-Is-Broken-300x220.jpg 300w\" sizes=\"auto, (max-width: 498px) 100vw, 498px\" \/><\/a><br \/>\nI also noticed it has ATMELH8202ECL? and a 24LDERB?? Possible NFC\/RFID?Attached to the antenna on the bottom? I did not see any FCC ID on the Scale.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-24LDERB-ATMELH8202ECL-2-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-133031 size-medium\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-24LDERB-ATMELH8202ECL-2-300x169.jpg\" alt=\"\" width=\"300\" height=\"169\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-24LDERB-ATMELH8202ECL-2-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-24LDERB-ATMELH8202ECL-2-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-24LDERB-ATMELH8202ECL-2-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-24LDERB-ATMELH8202ECL-2-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-24LDERB-ATMELH8202ECL-2-2048x1152.jpg 2048w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a> <a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-24LDERB-ATMELH8202ECL-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-133032 size-medium\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-24LDERB-ATMELH8202ECL-300x169.jpg\" alt=\"\" width=\"300\" height=\"169\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-24LDERB-ATMELH8202ECL-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-24LDERB-ATMELH8202ECL-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-24LDERB-ATMELH8202ECL-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-24LDERB-ATMELH8202ECL-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-24LDERB-ATMELH8202ECL-2048x1152.jpg 2048w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Went thru the service manual and I have Set it up and All options\/modes it has are enabled.<br \/>\nNtoing the Incruments\u00a0 Changed<br \/>\nFrom<br \/>\n10 lb x 0.1 oz<br \/>\n149 lb x 0.5 oz<br \/>\nTo<br \/>\n10 lb x 0.1 oz<br \/>\n70 lb x 0.2 oz<br \/>\n149 lb x 0.5 oz<\/p>\n<p>Sadly no ethernet or bluetooth options installed I will keep an eye out for them on feebay.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-All-Modes-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-133037\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-All-Modes-1024x576.jpg\" alt=\"\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-All-Modes-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-All-Modes-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-All-Modes-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-All-Modes-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BC6L-BCA-222-60U-Pitney-Bowes-JP85-Scale-All-Modes-2048x1152.jpg 2048w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><\/p>\n<p>A friend has a Certified 25lb calibration weights he will be bring them by in the near future and will check it but having known weight it seems accurate.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Mettler Toledo BC60 BC6L BCA-222-60U (Pitney Bowes JP85) Scale Teardown While browsing through eBay, I stumbled upon a valuable addition for the shop\u2014a Pitney Bowes JP85, which is Just a rebranded Mettler Toledo BC60 Series BC6L scale. Despite having with a plastic platter, I discovered that the stainless platter from my existing Mettler Toledo PS60 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":133012,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"no","_lmt_disable":"no","footnotes":""},"categories":[1],"tags":[],"class_list":["post-133009","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-stevens-posts"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.8 (Yoast SEO v27.3) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown - Steven Rhine - Rhine Labs Blog \/ News<\/title>\n<meta name=\"description\" content=\"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.stevenrhine.com\/?p=133009\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown\" \/>\n<meta property=\"og:description\" content=\"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.stevenrhine.com\/?p=133009\" \/>\n<meta property=\"og:site_name\" content=\"Steven Rhine - Rhine Labs Blog \/ News\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ContractPilot\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ContractPilot\" \/>\n<meta property=\"article:published_time\" content=\"2024-01-01T12:55:38+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-01-01T14:41:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1440\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Steven Rhine\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Steven Rhine\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=133009#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=133009\"},\"author\":{\"name\":\"Steven Rhine\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/3c8de2f9dac688e562a88b86b9b140ab\"},\"headline\":\"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown\",\"datePublished\":\"2024-01-01T12:55:38+00:00\",\"dateModified\":\"2024-01-01T14:41:57+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=133009\"},\"wordCount\":560,\"publisher\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/3c8de2f9dac688e562a88b86b9b140ab\"},\"image\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=133009#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.stevenrhine.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-scaled.jpg\",\"articleSection\":[\"Steven Rhine's Posts\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=133009\",\"url\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=133009\",\"name\":\"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown - Steven Rhine - Rhine Labs Blog \\\/ News\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=133009#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=133009#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.stevenrhine.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-scaled.jpg\",\"datePublished\":\"2024-01-01T12:55:38+00:00\",\"dateModified\":\"2024-01-01T14:41:57+00:00\",\"description\":\"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=133009#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.stevenrhine.com\\\/?p=133009\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=133009#primaryimage\",\"url\":\"https:\\\/\\\/www.stevenrhine.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/www.stevenrhine.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-scaled.jpg\",\"width\":2560,\"height\":1440},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=133009#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.stevenrhine.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#website\",\"url\":\"https:\\\/\\\/www.stevenrhine.com\\\/\",\"name\":\"The Personal Blog Of Steven L. Rhine\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/3c8de2f9dac688e562a88b86b9b140ab\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.stevenrhine.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/3c8de2f9dac688e562a88b86b9b140ab\",\"name\":\"Steven Rhine\",\"logo\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.stevenrhine.com\",\"https:\\\/\\\/www.facebook.com\\\/ContractPilot\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCcWSYh0zTaPtVNQg7hq7jew\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown - Steven Rhine - Rhine Labs Blog \/ News","description":"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.stevenrhine.com\/?p=133009","og_locale":"en_US","og_type":"article","og_title":"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown","og_description":"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown","og_url":"https:\/\/www.stevenrhine.com\/?p=133009","og_site_name":"Steven Rhine - Rhine Labs Blog \/ News","article_publisher":"https:\/\/www.facebook.com\/ContractPilot","article_author":"https:\/\/www.facebook.com\/ContractPilot","article_published_time":"2024-01-01T12:55:38+00:00","article_modified_time":"2024-01-01T14:41:57+00:00","og_image":[{"width":2560,"height":1440,"url":"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-scaled.jpg","type":"image\/jpeg"}],"author":"Steven Rhine","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Steven Rhine","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.stevenrhine.com\/?p=133009#article","isPartOf":{"@id":"https:\/\/www.stevenrhine.com\/?p=133009"},"author":{"name":"Steven Rhine","@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/3c8de2f9dac688e562a88b86b9b140ab"},"headline":"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown","datePublished":"2024-01-01T12:55:38+00:00","dateModified":"2024-01-01T14:41:57+00:00","mainEntityOfPage":{"@id":"https:\/\/www.stevenrhine.com\/?p=133009"},"wordCount":560,"publisher":{"@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/3c8de2f9dac688e562a88b86b9b140ab"},"image":{"@id":"https:\/\/www.stevenrhine.com\/?p=133009#primaryimage"},"thumbnailUrl":"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-scaled.jpg","articleSection":["Steven Rhine's Posts"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.stevenrhine.com\/?p=133009","url":"https:\/\/www.stevenrhine.com\/?p=133009","name":"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown - Steven Rhine - Rhine Labs Blog \/ News","isPartOf":{"@id":"https:\/\/www.stevenrhine.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.stevenrhine.com\/?p=133009#primaryimage"},"image":{"@id":"https:\/\/www.stevenrhine.com\/?p=133009#primaryimage"},"thumbnailUrl":"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-scaled.jpg","datePublished":"2024-01-01T12:55:38+00:00","dateModified":"2024-01-01T14:41:57+00:00","description":"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown","breadcrumb":{"@id":"https:\/\/www.stevenrhine.com\/?p=133009#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.stevenrhine.com\/?p=133009"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.stevenrhine.com\/?p=133009#primaryimage","url":"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-scaled.jpg","contentUrl":"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2024\/01\/Mettler-Toledo-BC60-BCA-222-60U-Pitney-Bowes-JP85-Scale-scaled.jpg","width":2560,"height":1440},{"@type":"BreadcrumbList","@id":"https:\/\/www.stevenrhine.com\/?p=133009#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.stevenrhine.com\/"},{"@type":"ListItem","position":2,"name":"Mettler Toledo BC60 BCA-222-60U (Pitney Bowes JP85) Scale Teardown"}]},{"@type":"WebSite","@id":"https:\/\/www.stevenrhine.com\/#website","url":"https:\/\/www.stevenrhine.com\/","name":"The Personal Blog Of Steven L. Rhine","description":"","publisher":{"@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/3c8de2f9dac688e562a88b86b9b140ab"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.stevenrhine.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/3c8de2f9dac688e562a88b86b9b140ab","name":"Steven Rhine","logo":{"@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/image\/"},"sameAs":["http:\/\/www.stevenrhine.com","https:\/\/www.facebook.com\/ContractPilot","https:\/\/www.youtube.com\/channel\/UCcWSYh0zTaPtVNQg7hq7jew"]}]}},"modified_by":"Steven Rhine","_links":{"self":[{"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/posts\/133009","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=133009"}],"version-history":[{"count":16,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/posts\/133009\/revisions"}],"predecessor-version":[{"id":133040,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/posts\/133009\/revisions\/133040"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/media\/133012"}],"wp:attachment":[{"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=133009"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=133009"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=133009"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}