{"id":1548,"date":"2016-02-23T22:35:53","date_gmt":"2016-02-24T06:35:53","guid":{"rendered":"http:\/\/www.stevenrhine.com\/?p=1548"},"modified":"2025-05-09T21:44:05","modified_gmt":"2025-05-10T04:44:05","slug":"updating-electrical","status":"publish","type":"post","link":"https:\/\/www.stevenrhine.com\/?p=1548","title":{"rendered":"Updating Electrical Adding A 100A Sub Panel!"},"content":{"rendered":"<p>Updating my 30 Amp sub going to 100A due to growing collection of 240V Equipment.<\/p>\n<p>&#8220;CNC Lathe, CNC G0704 Mill, Miller Diversion 180 Tig,\u00a0 Miller 211 Mig, Miller 375 Plasma,\u00a0 Miller LMSW-52T Spot Welder, And 7.5hp Air Compressor! &#8221;<\/p>\n<p>The GE 100A Breakers hard to find around here! 1 breaker For Split Bus the other For a Sub Panel Feed.<\/p>\n<p>The hard part will be running the 1-1-1-3 Cable and Driving Ground Rods.<\/p>\n<p>2 100A GE Breakers (Hard to find around here)<\/p>\n<p><a href=\"http:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-19.jpeg\" rel=\"attachment wp-att-1545\"><img decoding=\"async\" class=\"alignnone size-medium wp-image-1545\" src=\"http:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-19-300x225.jpeg\" alt=\"image\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-19-300x225.jpeg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-19-768x576.jpeg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-19-1024x768.jpeg 1024w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Thanks to a good friend I got the Coil of 1-1-1-3 no local big box stores have 1awg platt etc. wanted me to get a reel!<br \/>\n<a href=\"http:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-33.jpeg\" rel=\"attachment wp-att-1567\"><img decoding=\"async\" class=\"alignnone size-medium wp-image-1567\" src=\"http:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-33-300x225.jpeg\" alt=\"image\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-33-300x225.jpeg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-33-768x576.jpeg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-33-1024x768.jpeg 1024w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Right Side, 3rd Down Swapped 60A Split Bus to 100A Max Breaker Load For Sub Section. Will Remove the 30A Heating on the Right side 2nd breaker down and replace with 100A to feed sub panel and Extend with 10awg 3m Scotch Lok&#8217;s and Move to the 30A In Red Feeding the existing 30A Garage Sub. While i am at it since the rest of the breakers are 40+ years old will replace with new&#8230; Still made in USA!<br \/>\n<a href=\"http:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-35-e1456268280942.jpeg\" rel=\"attachment wp-att-1590\"><img decoding=\"async\" class=\"alignnone size-medium wp-image-1590\" src=\"http:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-35-e1456268280942-225x300.jpeg\" alt=\"image\" width=\"225\" height=\"300\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-35-e1456268280942-225x300.jpeg 225w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-35-e1456268280942-768x1024.jpeg 768w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><\/a><\/p>\n<div class=\"pld-like-dislike-wrap pld-template-1\">\r\n    <div class=\"pld-like-wrap  pld-common-wrap\">\r\n    <a href=\"javascript:void(0)\" class=\"pld-like-trigger pld-like-dislike-trigger  \" title=\"\" data-post-id=\"1548\" data-trigger-type=\"like\" data-restriction=\"ip\" data-already-liked=\"0\">\r\n                        <i class=\"fas fa-thumbs-up\"><\/i>\r\n                <\/a>\r\n    <span class=\"pld-like-count-wrap pld-count-wrap\">0    <\/span>\r\n<\/div><div class=\"pld-dislike-wrap  pld-common-wrap\">\r\n    <a href=\"javascript:void(0)\" class=\"pld-dislike-trigger pld-like-dislike-trigger  \" title=\"\" data-post-id=\"1548\" data-trigger-type=\"dislike\" data-restriction=\"ip\" data-already-liked=\"0\">\r\n                        <i class=\"fas fa-thumbs-down\"><\/i>\r\n                <\/a>\r\n    <span class=\"pld-dislike-count-wrap pld-count-wrap\">0<\/span>\r\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Updating my 30 Amp sub going to 100A due to growing collection of 240V Equipment. &#8220;CNC Lathe, CNC G0704 Mill, Miller Diversion 180 Tig,\u00a0 Miller 211 Mig, Miller 375 Plasma,\u00a0 Miller LMSW-52T Spot Welder, And 7.5hp Air Compressor! &#8221; The GE 100A Breakers hard to find around here! 1 breaker For Split Bus the other [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"no","_lmt_disable":"no","footnotes":""},"categories":[1],"tags":[],"class_list":["post-1548","post","type-post","status-publish","format-standard","hentry","category-stevens-posts"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.1 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Updating Electrical Adding A 100A Sub Panel! - Steven Rhine - Rhine Labs Blog \/ News<\/title>\n<meta name=\"description\" content=\"Updating Electrical Adding A 100A Sub Panel!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.stevenrhine.com\/?p=1548\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Updating Electrical Adding A 100A Sub Panel!\" \/>\n<meta property=\"og:description\" content=\"Updating Electrical Adding A 100A Sub Panel!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.stevenrhine.com\/?p=1548\" \/>\n<meta property=\"og:site_name\" content=\"Steven Rhine - Rhine Labs Blog \/ News\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ContractPilot\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ContractPilot\" \/>\n<meta property=\"article:published_time\" content=\"2016-02-24T06:35:53+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-10T04:44:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-19.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"3264\" \/>\n\t<meta property=\"og:image:height\" content=\"2448\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Steven Rhine\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Steven Rhine\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=1548#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=1548\"},\"author\":{\"name\":\"Steven Rhine\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/3c8de2f9dac688e562a88b86b9b140ab\"},\"headline\":\"Updating Electrical Adding A 100A Sub Panel!\",\"datePublished\":\"2016-02-24T06:35:53+00:00\",\"dateModified\":\"2025-05-10T04:44:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=1548\"},\"wordCount\":192,\"publisher\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/3c8de2f9dac688e562a88b86b9b140ab\"},\"image\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=1548#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/www.stevenrhine.com\\\/wp-content\\\/uploads\\\/2016\\\/02\\\/image-19-300x225.jpeg\",\"articleSection\":[\"Steven Rhine's Posts\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=1548\",\"url\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=1548\",\"name\":\"Updating Electrical Adding A 100A Sub Panel! - Steven Rhine - Rhine Labs Blog \\\/ News\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=1548#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=1548#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/www.stevenrhine.com\\\/wp-content\\\/uploads\\\/2016\\\/02\\\/image-19-300x225.jpeg\",\"datePublished\":\"2016-02-24T06:35:53+00:00\",\"dateModified\":\"2025-05-10T04:44:05+00:00\",\"description\":\"Updating Electrical Adding A 100A Sub Panel!\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=1548#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.stevenrhine.com\\\/?p=1548\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=1548#primaryimage\",\"url\":\"https:\\\/\\\/www.stevenrhine.com\\\/wp-content\\\/uploads\\\/2016\\\/02\\\/image-19.jpeg\",\"contentUrl\":\"https:\\\/\\\/www.stevenrhine.com\\\/wp-content\\\/uploads\\\/2016\\\/02\\\/image-19.jpeg\",\"width\":3264,\"height\":2448},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=1548#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.stevenrhine.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Updating Electrical Adding A 100A Sub Panel!\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#website\",\"url\":\"https:\\\/\\\/www.stevenrhine.com\\\/\",\"name\":\"The Personal Blog Of Steven L. Rhine\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/3c8de2f9dac688e562a88b86b9b140ab\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.stevenrhine.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/3c8de2f9dac688e562a88b86b9b140ab\",\"name\":\"Steven Rhine\",\"logo\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.stevenrhine.com\",\"https:\\\/\\\/www.facebook.com\\\/ContractPilot\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCcWSYh0zTaPtVNQg7hq7jew\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Updating Electrical Adding A 100A Sub Panel! - Steven Rhine - Rhine Labs Blog \/ News","description":"Updating Electrical Adding A 100A Sub Panel!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.stevenrhine.com\/?p=1548","og_locale":"en_US","og_type":"article","og_title":"Updating Electrical Adding A 100A Sub Panel!","og_description":"Updating Electrical Adding A 100A Sub Panel!","og_url":"https:\/\/www.stevenrhine.com\/?p=1548","og_site_name":"Steven Rhine - Rhine Labs Blog \/ News","article_publisher":"https:\/\/www.facebook.com\/ContractPilot","article_author":"https:\/\/www.facebook.com\/ContractPilot","article_published_time":"2016-02-24T06:35:53+00:00","article_modified_time":"2025-05-10T04:44:05+00:00","og_image":[{"width":3264,"height":2448,"url":"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-19.jpeg","type":"image\/jpeg"}],"author":"Steven Rhine","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Steven Rhine","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.stevenrhine.com\/?p=1548#article","isPartOf":{"@id":"https:\/\/www.stevenrhine.com\/?p=1548"},"author":{"name":"Steven Rhine","@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/3c8de2f9dac688e562a88b86b9b140ab"},"headline":"Updating Electrical Adding A 100A Sub Panel!","datePublished":"2016-02-24T06:35:53+00:00","dateModified":"2025-05-10T04:44:05+00:00","mainEntityOfPage":{"@id":"https:\/\/www.stevenrhine.com\/?p=1548"},"wordCount":192,"publisher":{"@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/3c8de2f9dac688e562a88b86b9b140ab"},"image":{"@id":"https:\/\/www.stevenrhine.com\/?p=1548#primaryimage"},"thumbnailUrl":"http:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-19-300x225.jpeg","articleSection":["Steven Rhine's Posts"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.stevenrhine.com\/?p=1548","url":"https:\/\/www.stevenrhine.com\/?p=1548","name":"Updating Electrical Adding A 100A Sub Panel! - Steven Rhine - Rhine Labs Blog \/ News","isPartOf":{"@id":"https:\/\/www.stevenrhine.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.stevenrhine.com\/?p=1548#primaryimage"},"image":{"@id":"https:\/\/www.stevenrhine.com\/?p=1548#primaryimage"},"thumbnailUrl":"http:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-19-300x225.jpeg","datePublished":"2016-02-24T06:35:53+00:00","dateModified":"2025-05-10T04:44:05+00:00","description":"Updating Electrical Adding A 100A Sub Panel!","breadcrumb":{"@id":"https:\/\/www.stevenrhine.com\/?p=1548#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.stevenrhine.com\/?p=1548"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.stevenrhine.com\/?p=1548#primaryimage","url":"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-19.jpeg","contentUrl":"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2016\/02\/image-19.jpeg","width":3264,"height":2448},{"@type":"BreadcrumbList","@id":"https:\/\/www.stevenrhine.com\/?p=1548#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.stevenrhine.com\/"},{"@type":"ListItem","position":2,"name":"Updating Electrical Adding A 100A Sub Panel!"}]},{"@type":"WebSite","@id":"https:\/\/www.stevenrhine.com\/#website","url":"https:\/\/www.stevenrhine.com\/","name":"The Personal Blog Of Steven L. Rhine","description":"","publisher":{"@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/3c8de2f9dac688e562a88b86b9b140ab"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.stevenrhine.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/3c8de2f9dac688e562a88b86b9b140ab","name":"Steven Rhine","logo":{"@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/image\/"},"sameAs":["http:\/\/www.stevenrhine.com","https:\/\/www.facebook.com\/ContractPilot","https:\/\/www.youtube.com\/channel\/UCcWSYh0zTaPtVNQg7hq7jew"]}]}},"modified_by":"Steven Rhine","_links":{"self":[{"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/posts\/1548","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1548"}],"version-history":[{"count":2,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/posts\/1548\/revisions"}],"predecessor-version":[{"id":136641,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/posts\/1548\/revisions\/136641"}],"wp:attachment":[{"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1548"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1548"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1548"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}