{"id":4019,"date":"2022-09-10T22:00:11","date_gmt":"2022-09-11T05:00:11","guid":{"rendered":"http:\/\/www.stevenrhine.com\/?p=4019"},"modified":"2026-06-09T11:33:20","modified_gmt":"2026-06-09T18:33:20","slug":"xeltek-superpro-3000u-programmer-calibration-procedure","status":"publish","type":"post","link":"https:\/\/www.stevenrhine.com\/?p=4019","title":{"rendered":"Xeltek SuperPro 3000U Programmer Calibration Procedure"},"content":{"rendered":"<h3>Xeltek <a href=\"https:\/\/www.xeltek-cn.com\/en\/sp3000u.html\">SuperPro 3000U<\/a> Programmer Calibration Procedure.<\/h3>\n<p>Common <em>Xeltek Superpro 3000U<\/em> Issues: Leaking Electrolytic Capacitors &amp; Faulty MC34063 1.5 to 40v Inverter Regulators.<\/p>\n<p><a href=\"https:\/\/www.stevenrhine.com\/?p=130353\">See My Full Xeltek Superpro 3000U Teardown<\/a> (I Lost 1\/2 the video and all audio so I have to redo it oops)<\/p>\n<p>These programmers are pushing 20 years old and showing their age. I decided to open mine up for inspection since it does more sitting in a cabinet than earning now days. I checked my electrolytic capacitors in-curcit with an ESR meter they check acceptable no electrolytic leakage was seen.<\/p>\n<p>Regardless if the capacitors read within acceptable limits after 18 or so years all the Electrolytic capacitors should be replaced. So, Yes! I will be replacing them with some quality Rubycon and Nichicon caps before the dreaded leakage starts and pcb damage occurs. A List of the electrolytic capacitors is provided at the bottom of the post as is a Mouser Project List. Overall parts cost for capacitors is about $6.00 + shipping. A Small price to pay for preventative maintenance.<\/p>\n<p>Following any repairs you need to check calibration more then likely you will need to calibrate the programmer.<\/p>\n<p><strong>Now on to the Calibration Procedure.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050352-scaled.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130383\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050352-1024x576.jpg\" alt=\"\" width=\"502\" height=\"282\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050352-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050352-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050352-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050352-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050352-2048x1152.jpg 2048w\" sizes=\"(max-width: 502px) 100vw, 502px\" \/><\/a><\/strong><\/p>\n<p><em>Tools Required For Calibration Procedure<\/em><br \/>\n<em>#1\u00a0 Phillips Screw Driver<\/em><br \/>\n<em>2mm non metallic pot adjust driver (Ceramic)<\/em><br \/>\n<em>Quality Digital Multi Meter 4.5 to 6.5 Digit Resolution (Fluke, Siglent, BK, Agilent, Etc) <\/em><br \/>\n<em>ESR Meter to Check Capacitors<\/em><\/p>\n<p>(If you Elect to or have to change the electrolytic capacitors out or have a faulty 1.5 to 40v inverter regulator the appropriate soldering\/desoldering equipment, flux and solder is required)<\/p>\n<p>If you do not feel conformable doing this contact me on the <a href=\"https:\/\/www.facebook.com\/groups\/xeltek\/\">Xeltek Superpro User Group<\/a> I can do it for you for a small fee + parts and shipping.<\/p>\n<p>1) Download and install the test software for the Superpro 3000U from Xeltek (<a href=\"http:\/\/www.xeltek.com\/software\/sp3000u\/sp3000uTEST.zip\">Here<\/a>) or (<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/sp3000uTEST-Archive.zip\">Archive<\/a>)<br \/>\n2) Open the Xeltek Superpro 3000U by removing the socket adapter on the top of the unit and the four screws on the bottom of the unit.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050258-scaled.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130385\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050258-1024x576.jpg\" alt=\"\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050258-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050258-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050258-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050258-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050258-2048x1152.jpg 2048w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/a> <a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050646-scaled.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130384\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050646-1024x576.jpg\" alt=\"\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050646-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050646-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050646-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050646-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_050646-2048x1152.jpg 2048w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/a><\/p>\n<p>When lifting the top off do not loose the 4 standoffs and Carefully remove the power switch from the top half of the case so that the top half of the case can be folded forward with all of the cables still connected.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045601-scaled-e1662902922866.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130386\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045601-scaled-e1662902922866-1024x660.jpg\" alt=\"\" width=\"500\" height=\"322\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045601-scaled-e1662902922866-1024x660.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045601-scaled-e1662902922866-300x193.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045601-scaled-e1662902922866-768x495.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045601-scaled-e1662902922866-1536x991.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045601-scaled-e1662902922866-2048x1321.jpg 2048w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/a> <a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045536-scaled-e1662902884512.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130387\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045536-scaled-e1662902884512-1024x646.jpg\" alt=\"\" width=\"500\" height=\"315\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045536-scaled-e1662902884512-1024x646.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045536-scaled-e1662902884512-300x189.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045536-scaled-e1662902884512-768x484.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045536-scaled-e1662902884512-1536x968.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045536-scaled-e1662902884512-2048x1291.jpg 2048w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/a><\/p>\n<p>Take note the membrane key pad flex cable is very short Use Caution when disconnecting cable form the header do not pull from flex cable you will damage this cable and replacement membranes are not available. Carefully Pull form the black header connector only! You Will Now have Un Obstructed Access to VR1, Vr2, VR3, &amp; VR4<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045357-scaled.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130388\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045357-1024x576.jpg\" alt=\"\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045357-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045357-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045357-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045357-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045357-2048x1152.jpg 2048w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/> <\/a><a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045329-scaled.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130389\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045329-1024x576.jpg\" alt=\"\" width=\"500\" height=\"282\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045329-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045329-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045329-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045329-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/20220911_045329-2048x1152.jpg 2048w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/a><br \/>\nPhoto below showing the cover completely removed.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-scaled.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130346\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-1024x573.jpg\" alt=\"\" width=\"500\" height=\"280\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-1024x573.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-300x168.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-768x430.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-1536x860.jpg 1536w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/a><br \/>\n3) Reinstall the socket adapter onto the main board (White Connectors).<br \/>\n(Photo Missing Opps)<br \/>\n4) Plug in power and USB to computer and turn on the 3000U. Allow programmer to warm up for 30min or so.<\/p>\n<p>Location of the 3 LM317T Linear Voltage Regulators 1.2-37V Adj at Q54, Q55, &amp; Q56.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulators-Location-scaled.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130343 \" title=\"Xeltek Superpro 3000U 3 LM317T Voltage Regulators Q54 Q55 Q56\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulators-Location-1024x576.jpg\" alt=\"Xeltek Superpro 3000U 3 LM317T Voltage Regulators Q54 Q55 Q56\" width=\"500\" height=\"281\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulators-Location-1024x576.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulators-Location-300x169.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulators-Location-768x432.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulators-Location-1536x864.jpg 1536w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulators-Location-2048x1152.jpg 2048w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/a><br \/>\n5) Adjust VR4 for best contrast on the LCD display.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR4-Location.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130342 \" title=\"Xeltek Superpro 3000U Voltege Regulator VR4 Contrast Adjust Location\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR4-Location-859x1024.jpg\" alt=\"Xeltek Superpro 3000U Voltege Regulator VR4 Contrast Adjust Location\" width=\"499\" height=\"595\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR4-Location-859x1024.jpg 859w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR4-Location-252x300.jpg 252w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR4-Location-768x915.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR4-Location-1289x1536.jpg 1289w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR4-Location-1718x2048.jpg 1718w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR4-Location.jpg 1893w\" sizes=\"(max-width: 499px) 100vw, 499px\" \/><\/a><br \/>\n6) Launch the SUPERPRO for Windows software. Click on the &#8216;Device&#8217; Button. Type &#8216;XELTEK&#8217; without the quotes into the search box. Select the device called &#8216;##################11111111111111&#8217; and press the &#8216;OK&#8217; button.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Test-Algo.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130391\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Test-Algo.jpg\" alt=\"\" width=\"500\" height=\"363\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Test-Algo.jpg 706w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Test-Algo-300x218.jpg 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/a><br \/>\nSelect &#8216;Calibrate&#8217; from the list of operations.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Calibrate.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130392\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Calibrate.jpg\" alt=\"\" width=\"502\" height=\"519\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Calibrate.jpg 498w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Calibrate-290x300.jpg 290w\" sizes=\"(max-width: 502px) 100vw, 502px\" \/><\/a><\/p>\n<p>Selecting Calibrate the programmer will run. This will apply <strong>12.0V<\/strong> to <strong>Pin 1<\/strong> of the test socket, <strong>9.0V<\/strong> to <strong>Pin 48<\/strong>, and <strong>5V<\/strong> to <strong>Pin 25<\/strong> for several seconds. All voltages are referenced to <strong>Pin 2<\/strong> which is <strong>Ground<\/strong>. Go slow adjust one VR pot at a time. Again, It is best to use a quality 5.5 or 6.5 Digit Multi Meter for the adjustments you want the 12V, 9V and 5V voltages as accurate as possible.<\/p>\n<p>7) Adjust VR1. Set the voltage at pin 1 on the test socket to be exactly 12V.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR1-Location.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130339 \" title=\"Xeltek Superpro 3000U Voltege Regulator VR1 Location\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR1-Location-813x1024.jpg\" alt=\"Xeltek Superpro 3000U Voltege Regulator VR1 Location\" width=\"498\" height=\"627\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR1-Location-813x1024.jpg 813w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR1-Location-238x300.jpg 238w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR1-Location-768x968.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR1-Location-1219x1536.jpg 1219w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR1-Location-1625x2048.jpg 1625w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR1-Location.jpg 1792w\" sizes=\"(max-width: 498px) 100vw, 498px\" \/><\/a><br \/>\n8) Adjust VR2, Set the voltage at pin 48 on the test socket to be exactly 9V.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR2-Location.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130340 \" title=\"Xeltek Superpro 3000U Voltege Regulator VR2 Location\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR2-Location-988x1024.jpg\" alt=\"Xeltek Superpro 3000U Voltege Regulator VR2 Location\" width=\"504\" height=\"522\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR2-Location-988x1024.jpg 988w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR2-Location-290x300.jpg 290w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR2-Location-768x796.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR2-Location-1482x1536.jpg 1482w\" sizes=\"(max-width: 504px) 100vw, 504px\" \/><\/a><br \/>\n9) Adjust VR3, Set the voltage at pin 25 on the test socket to be exactly 5V<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR3-Location-scaled.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130341 \" title=\"Xeltek Superpro 3000U Voltege Regulator VR3 Location\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR3-Location-1024x735.jpg\" alt=\"Xeltek Superpro 3000U Voltege Regulator VR3 Location\" width=\"500\" height=\"359\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR3-Location-1024x735.jpg 1024w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR3-Location-300x215.jpg 300w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR3-Location-768x551.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-VR3-Location-1536x1103.jpg 1536w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/a>.<br \/>\n10) Click on Calibration again and verify 12V, 9V and 5V voltages if present then\u00a0 calibration of the Xeltek SuperPro 3000U is complete Reassemble (dont forget the standoffs) you are done. Go burn some chips.<\/p>\n<p>Otherwise, If the voltages cannot be brought into spec (too low) or if the unit will not program high voltage devices (such as 2716&#8217;s or 8748&#8217;s) then the problem is likely with the <a href=\"https:\/\/www.mouser.com\/datasheet\/2\/308\/MC34063A_D-1811395.pdf\">MC34063AP1G<\/a> 1.5 to 40V Inverting regulator ICs Located at U10 and U11. Replace these ICs and all should be working again. Current Mouser Replacements\u00a0 TI <a href=\"https:\/\/www.mouser.com\/ProductDetail\/Texas-Instruments\/MC34063AP?qs=paYhMW8qfiu1umxNjP0GEg%3D%3D\">MC34063AP<\/a>.<br \/>\n<a href=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2020\/04\/Xeltek-Superpro-3000U-Voltege-Switching-Regulators-Location.jpg\"><img decoding=\"async\" class=\"alignnone wp-image-130348 \" title=\"Xeltek Superpro 3000U Voltege Switching Regulators MC34063 Location\" src=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2020\/04\/Xeltek-Superpro-3000U-Voltege-Switching-Regulators-Location-858x1024.jpg\" alt=\"Xeltek Superpro 3000U Voltege Switching Regulators MC34063 Location\" width=\"499\" height=\"596\" srcset=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2020\/04\/Xeltek-Superpro-3000U-Voltege-Switching-Regulators-Location-858x1024.jpg 858w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2020\/04\/Xeltek-Superpro-3000U-Voltege-Switching-Regulators-Location-251x300.jpg 251w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2020\/04\/Xeltek-Superpro-3000U-Voltege-Switching-Regulators-Location-768x916.jpg 768w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2020\/04\/Xeltek-Superpro-3000U-Voltege-Switching-Regulators-Location-1287x1536.jpg 1287w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2020\/04\/Xeltek-Superpro-3000U-Voltege-Switching-Regulators-Location-1716x2048.jpg 1716w, https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2020\/04\/Xeltek-Superpro-3000U-Voltege-Switching-Regulators-Location.jpg 1900w\" sizes=\"(max-width: 499px) 100vw, 499px\" \/><\/a><\/p>\n<p>Additionally when replacing the MC3406AP It is recommend to socket the replacements as they seem to be a high-failure item. Turning the unit off when not in use should make it last longer as these ICs run whenever it is on.<\/p>\n<p>Xeltek Superpro 3000U Electrolytic Capacitor List<\/p>\n<p>10uf 50V X 3 (C69, C68, C67)<br \/>\n1uf 50V X 2 (C65, C57)<br \/>\n470uf 35V X 1 (C56)<br \/>\n470uf 16V X 1\u00a0 (C55)<br \/>\n470uf 25V X 1 (C54)<br \/>\n22uf 50V x 5 (C61, C62, C58, C59, C60)<\/p>\n<p><a href=\"https:\/\/www.mouser.com\/ProjectManager\/ProjectDetail.aspx?AccessID=f3a4150d70\">Mouser Project List<\/a> (Verify Whats Installed on Your Programmer)<\/p>\n<h4><em><strong>Xeltek Suprpro 3000U <\/strong><\/em><br \/>\n<strong>Right to Repair Score: Undetermined<\/strong><\/h4>\n<p>&nbsp;<\/p>\n<div class=\"pld-like-dislike-wrap pld-template-1\">\r\n    <div class=\"pld-like-wrap  pld-common-wrap\">\r\n    <a href=\"javascript:void(0)\" class=\"pld-like-trigger pld-like-dislike-trigger  \" title=\"\" data-post-id=\"4019\" data-trigger-type=\"like\" data-restriction=\"ip\" data-already-liked=\"0\">\r\n                        <i class=\"fas fa-thumbs-up\"><\/i>\r\n                <\/a>\r\n    <span class=\"pld-like-count-wrap pld-count-wrap\">0    <\/span>\r\n<\/div><div class=\"pld-dislike-wrap  pld-common-wrap\">\r\n    <a href=\"javascript:void(0)\" class=\"pld-dislike-trigger pld-like-dislike-trigger  \" title=\"\" data-post-id=\"4019\" data-trigger-type=\"dislike\" data-restriction=\"ip\" data-already-liked=\"0\">\r\n                        <i class=\"fas fa-thumbs-down\"><\/i>\r\n                <\/a>\r\n    <span class=\"pld-dislike-count-wrap pld-count-wrap\">0<\/span>\r\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Xeltek SuperPro 3000U Programmer Calibration Procedure. Common Xeltek Superpro 3000U Issues: Leaking Electrolytic Capacitors &amp; Faulty MC34063 1.5 to 40v Inverter Regulators. See My Full Xeltek Superpro 3000U Teardown (I Lost 1\/2 the video and all audio so I have to redo it oops) These programmers are pushing 20 years old and showing their age. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":130346,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"no","_lmt_disable":"no","footnotes":""},"categories":[1],"tags":[],"class_list":["post-4019","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-stevens-posts"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.1 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Xeltek SuperPro 3000U Programmer Calibration Procedure<\/title>\n<meta name=\"description\" content=\"Xeltek SuperPro 3000U Calibration Procedure. Replacement Electrolytic Capacitor List\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.stevenrhine.com\/?p=4019\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Xeltek SuperPro 3000U Programmer Calibration Procedure\" \/>\n<meta property=\"og:description\" content=\"Xeltek SuperPro 3000U Calibration Procedure. Replacement Electrolytic Capacitor List\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.stevenrhine.com\/?p=4019\" \/>\n<meta property=\"og:site_name\" content=\"Steven Rhine - Rhine Labs Blog \/ News\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ContractPilot\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ContractPilot\" \/>\n<meta property=\"article:published_time\" content=\"2022-09-11T05:00:11+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-09T18:33:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1433\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Steven Rhine\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Steven Rhine\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=4019#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=4019\"},\"author\":{\"name\":\"Steven Rhine\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/3c8de2f9dac688e562a88b86b9b140ab\"},\"headline\":\"Xeltek SuperPro 3000U Programmer Calibration Procedure\",\"datePublished\":\"2022-09-11T05:00:11+00:00\",\"dateModified\":\"2026-06-09T18:33:20+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=4019\"},\"wordCount\":839,\"publisher\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/3c8de2f9dac688e562a88b86b9b140ab\"},\"image\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=4019#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.stevenrhine.com\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-scaled.jpg\",\"articleSection\":[\"Steven Rhine's Posts\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=4019\",\"url\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=4019\",\"name\":\"Xeltek SuperPro 3000U Programmer Calibration Procedure\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=4019#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=4019#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.stevenrhine.com\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-scaled.jpg\",\"datePublished\":\"2022-09-11T05:00:11+00:00\",\"dateModified\":\"2026-06-09T18:33:20+00:00\",\"description\":\"Xeltek SuperPro 3000U Calibration Procedure. Replacement Electrolytic Capacitor List\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=4019#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.stevenrhine.com\\\/?p=4019\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=4019#primaryimage\",\"url\":\"https:\\\/\\\/www.stevenrhine.com\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/www.stevenrhine.com\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-scaled.jpg\",\"width\":2560,\"height\":1433},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/?p=4019#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.stevenrhine.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Xeltek SuperPro 3000U Programmer Calibration Procedure\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#website\",\"url\":\"https:\\\/\\\/www.stevenrhine.com\\\/\",\"name\":\"The Personal Blog Of Steven L. Rhine\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/3c8de2f9dac688e562a88b86b9b140ab\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.stevenrhine.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/3c8de2f9dac688e562a88b86b9b140ab\",\"name\":\"Steven Rhine\",\"logo\":{\"@id\":\"https:\\\/\\\/www.stevenrhine.com\\\/#\\\/schema\\\/person\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.stevenrhine.com\",\"https:\\\/\\\/www.facebook.com\\\/ContractPilot\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCcWSYh0zTaPtVNQg7hq7jew\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Xeltek SuperPro 3000U Programmer Calibration Procedure","description":"Xeltek SuperPro 3000U Calibration Procedure. Replacement Electrolytic Capacitor List","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.stevenrhine.com\/?p=4019","og_locale":"en_US","og_type":"article","og_title":"Xeltek SuperPro 3000U Programmer Calibration Procedure","og_description":"Xeltek SuperPro 3000U Calibration Procedure. Replacement Electrolytic Capacitor List","og_url":"https:\/\/www.stevenrhine.com\/?p=4019","og_site_name":"Steven Rhine - Rhine Labs Blog \/ News","article_publisher":"https:\/\/www.facebook.com\/ContractPilot","article_author":"https:\/\/www.facebook.com\/ContractPilot","article_published_time":"2022-09-11T05:00:11+00:00","article_modified_time":"2026-06-09T18:33:20+00:00","og_image":[{"width":2560,"height":1433,"url":"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-scaled.jpg","type":"image\/jpeg"}],"author":"Steven Rhine","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Steven Rhine","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.stevenrhine.com\/?p=4019#article","isPartOf":{"@id":"https:\/\/www.stevenrhine.com\/?p=4019"},"author":{"name":"Steven Rhine","@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/3c8de2f9dac688e562a88b86b9b140ab"},"headline":"Xeltek SuperPro 3000U Programmer Calibration Procedure","datePublished":"2022-09-11T05:00:11+00:00","dateModified":"2026-06-09T18:33:20+00:00","mainEntityOfPage":{"@id":"https:\/\/www.stevenrhine.com\/?p=4019"},"wordCount":839,"publisher":{"@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/3c8de2f9dac688e562a88b86b9b140ab"},"image":{"@id":"https:\/\/www.stevenrhine.com\/?p=4019#primaryimage"},"thumbnailUrl":"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-scaled.jpg","articleSection":["Steven Rhine's Posts"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.stevenrhine.com\/?p=4019","url":"https:\/\/www.stevenrhine.com\/?p=4019","name":"Xeltek SuperPro 3000U Programmer Calibration Procedure","isPartOf":{"@id":"https:\/\/www.stevenrhine.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.stevenrhine.com\/?p=4019#primaryimage"},"image":{"@id":"https:\/\/www.stevenrhine.com\/?p=4019#primaryimage"},"thumbnailUrl":"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-scaled.jpg","datePublished":"2022-09-11T05:00:11+00:00","dateModified":"2026-06-09T18:33:20+00:00","description":"Xeltek SuperPro 3000U Calibration Procedure. Replacement Electrolytic Capacitor List","breadcrumb":{"@id":"https:\/\/www.stevenrhine.com\/?p=4019#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.stevenrhine.com\/?p=4019"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.stevenrhine.com\/?p=4019#primaryimage","url":"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-scaled.jpg","contentUrl":"https:\/\/www.stevenrhine.com\/wp-content\/uploads\/2022\/09\/Xeltek-Superpro-3000U-Voltege-Regulator-Location-Cover-Off-scaled.jpg","width":2560,"height":1433},{"@type":"BreadcrumbList","@id":"https:\/\/www.stevenrhine.com\/?p=4019#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.stevenrhine.com\/"},{"@type":"ListItem","position":2,"name":"Xeltek SuperPro 3000U Programmer Calibration Procedure"}]},{"@type":"WebSite","@id":"https:\/\/www.stevenrhine.com\/#website","url":"https:\/\/www.stevenrhine.com\/","name":"The Personal Blog Of Steven L. Rhine","description":"","publisher":{"@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/3c8de2f9dac688e562a88b86b9b140ab"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.stevenrhine.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/3c8de2f9dac688e562a88b86b9b140ab","name":"Steven Rhine","logo":{"@id":"https:\/\/www.stevenrhine.com\/#\/schema\/person\/image\/"},"sameAs":["http:\/\/www.stevenrhine.com","https:\/\/www.facebook.com\/ContractPilot","https:\/\/www.youtube.com\/channel\/UCcWSYh0zTaPtVNQg7hq7jew"]}]}},"modified_by":"Steven Rhine","_links":{"self":[{"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/posts\/4019","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4019"}],"version-history":[{"count":5,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/posts\/4019\/revisions"}],"predecessor-version":[{"id":133006,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/posts\/4019\/revisions\/133006"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=\/wp\/v2\/media\/130346"}],"wp:attachment":[{"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4019"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=4019"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.stevenrhine.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=4019"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}